Industrial SHT35 deployment
Review how precision, customization and RS485 Modbus fit industrial environmental monitoring decisions.
Read deployment articleRS485 Modbus Monitoring Planning
Plan an SHT35 RS485 Modbus transmitter with VOTESEN when your project needs an OEM humidity sensor manufacturer and a configurable humidity temperature sensor for PLC, DCS, host computer or environmental monitoring systems.
Interface Fit
The project fit is not only the sensor chip. The transmitter, probe housing, cable, RS485 bus and host system all need to work as one measurement path.
Start with the Sensirion SHT35 humidity and temperature measurement requirement, including tolerance, resolution and the air path around the probe.
Confirm probe form, cable material and cable length so the transmitter can be placed where humidity and temperature data are actually needed.
Use the listed Modbus-RTU communication path when the project needs a digital bus instead of a simple analog signal.
Plan baud rate, byte format and addressing with the receiving system before installation so field data can be read reliably.
Project Checks
The SHT35 transmitter is most useful when its electrical, protocol and environmental limits are checked before the order is configured.
| Product identity | SHT35 Digital Environmental Monitoring Sensors RS485 Modbus |
|---|---|
| Sensor chip | SHT35; customizable chip choice is listed for ordering discussions. |
| Supply voltage | DC 4.5V-24V |
| Accuracy | Temperature +/-0.1 C; humidity +/-1.5%RH |
| Resolution | 0.1 C; 0.1%RH |
| Working range | -30 - 80 C; 0%RH - 90%RH |
| Protocol | RS485 / Modbus-RTU |
| Communication setup | 1200, 2400, 4800, 9600 and 19200 baud are listed as configurable; default 9600bps. Byte format: 8 data bits, 1 stop bit, no parity. |
Use the accuracy, resolution and RS485 path when planning climate chambers, computer rooms, weather stations or building automation monitoring.
Confirm probe exposure, cable routing and measurement placement when humidity shifts can affect crops, storage or field monitoring conditions.
Match cable material, cable length and output to pharmaceutical, paper, food, electronic, warehouse or other named facilities.
Related Sensor Options
Use the SHT35 RS485 transmitter when Modbus monitoring is required, and review related models when the project points toward I2C output, another SHT generation or an analog transmitter.

I2C module option for industrial OEM projects that do not need the same RS485 transmitter format.
Review SHT30
A precision SHT4x family option for projects considering low-power digital humidity and temperature measurement.
Review SHT45
An I2C output model to review when the system design favors compact digital sensor components.
Review SHT41
A wall-mount transmitter path for HVAC and automation projects that need an analog output format.
Review 0-10V optionInquiry Inputs
A clear inquiry helps VOTESEN align the SHT35 transmitter with the installation environment, host interface and field wiring plan.
State the SHT sensor chip and probe requirement, including whether a PE probe or another housing choice is needed.
Choose cable material such as PVC, silicone or UV-resistant cable according to heat, moisture, routing and outdoor exposure.
Share the needed length, such as 1 m, 2 m, 5 m, 10 m or 15 m, so the sensing point can be placed correctly.
Confirm RS485 Modbus output needs and note any connector requirement before wiring and host-system planning.
Describe the greenhouse, HVAC, warehouse, computer room, production or other monitoring environment.
Provide quantity and deployment count so the quotation can reflect project scale and repeated installation needs.
Technical Reading
These three VOTESEN articles support different planning questions: industrial deployment, RS485 data transmission and agriculture or greenhouse monitoring.

Review how precision, customization and RS485 Modbus fit industrial environmental monitoring decisions.
Read deployment article
Check what matters when environmental data must move through a stable, noise-resistant digital interface.
Read RS485 article
Review monitoring considerations for crops, greenhouses and other environments where humidity shifts matter.
Read greenhouse articleFAQ
The SHT35 transmitter uses an RS485 bus with MODBUS-RTU protocol, so it can be planned for PLC, DCS, host computer and other monitoring systems that accept RS485 Modbus data.
The listed SHT35 accuracy is temperature +/-0.1 C and humidity +/-1.5%RH, with 0.1 C and 0.1%RH resolution. Use those values when checking whether the sensor fits the required monitoring tolerance.
Named uses include agriculture, building automation, meteorology, climate chambers, weather stations, HVAC, greenhouses, forestry, computer room monitoring, warehousing and storage or production facilities.
Prepare the SHT sensor chip, probe type, cable material, cable length, output, connector requirement and order quantity so the team can match the transmitter to the installation.
The product page lists cable material options such as PVC, silicone and UV-resistant cable, with example lengths including 1 m, 2 m, 5 m, 10 m and 15 m. Confirm the final cable choice for the operating environment.
Review related SHT30, SHT41, SHT45 or 0-10V transmitter options when the project needs a different interface, mounting format or monitoring output than the SHT35 RS485 Modbus transmitter.